Authors: Vaclav Vacek Vaclav Vinš
Publish Date: 2007/10/16
Volume: 28, Issue: 5, Pages: 1490-1508
Abstract
Capillary tube expansion devices are widely used in refrigeration equipment nevertheless the mechanism of the flow is still not fully described and understood so the experimental verification of most predictions is still necessary A modified numerical model of capillary flow has been developed both for standard refrigerants and with emphasis for saturated fluorocarbon C2F2n+2 refrigerants These refrigerants have several unique properties high dielectric performance chemical stability and radiation resistance Therefore they can be used in some special applications where other common fluids cannot be applied The main aim of this study was to prepare a practical capillary flow model which would improve the procedure of predicting the behavior of capillary tubes for cooling circuits of particle detectors being built at the international CERN laboratory in Geneva The generated numerical model was verified through available data from the literature and also via measurements performed in a real cooling circuit with pure oilfree octafluoropropane C3F8 refrigerant
Keywords: